Table 5- 40 Technical specifications for Motor Modules in chassis format, line voltage 500 to 690 V 3 ph. AC, DC-link
voltage 675 to 1035 V DC; part III
- for I
L
(50 Hz 690 V)
1)
- for I
H
(50 Hz 690 V)
1)
- for I
L
(50 Hz 500 V)
1)
- for I
H
(50 Hz 500 V)
1)
- for I
L
(60 Hz 575 V)
2)
H
2)
kW
kW
kW
kW
HP
710
630
500
450
700
800
710
560
500
800
900
800
630
560
900
1000
900
710
630
1000
1200
1000
900
800
1250
- Rated current I
N A
- Base load current I
L
3)
- Base load current I
H
4)
A
A
A
735
710
657
810
790
724
910
880
814
1025
1000
917
1270
1230
1136
Rated current I
N DC
when supplied via:
- Basic/Smart Line Module
- Active Line Module
- Base load current I
L DC
3)
when supplied via:
- Basic/Smart Line Module
- Active Line Module
- Base load current I
H DC
4)
when supplied via:
- Basic/Smart Line Module
- Active Line Module
A
A
A
A
A
A
882
794
859
774
784
706
972
875
947
853
865
778
1092
983
1064
958
971
874
1230
1107
1199
1079
1094
985
1524
1372
1485
1337
1356
1221
- DC-link voltage
- Electronic power supply
V
DC
V
DC
ACrms
675 to 1035
24 (20.4 to 28.8)
0 to 0.72 x DC-link voltage
- Auxiliary supply 24 V DC
A
1.25
1.25
1.4
1.4
1.4
- Rated frequency
- Pulse frequency, max.
- without current derating
kHz
kHz
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
5)
- at 50 Hz 690 V
kW
10.9
11.5
11.7
13.2
16.0
cfm
3
2288
2288
2288
2288
2288
pA
Motor connection U2, V2, W2
- Screws
- Max. conductor cross-section (IEC)
- Max. conductor cross-section (NEC, CEC)
mm
2
3/M12
6 x 240
3/M12
6 x 240
3/M12
6 x 240
3/M12
6 x 240
3/M12
6 x 240