EasyManua.ls Logo

Siemens SINAMICS S120 - K52, Additional SMC30 Sensor Module

Siemens SINAMICS S120
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
8.13 K52, Additional SMC30 Sensor Module
Cabinet Modules NEMA
388 Manual, 04/2014, A5E03586450A
Removing the connector jumper in the VSM10 Voltage Sensing Module
If a device is operated on an ungrounded system (IT system), the connector jumper in
terminal X530 on the bottom of the component must be removed from the Voltage Sensing
Module (VSM10).
Use two screwdrivers or a suitable tool in order to relieve the holding springs in the terminal
and then pull the connector jumper.
Terminal X530 with connector jumper
Relieve the springs and pull the connector jumper
8.13
K52, Additional SMC30 Sensor Module
Availability of option
This option is available for the following S120 Cabinet Modules:
Booksize Cabinet Kits
Motor Modules in chassis format
Description
With option K50, the cabinet unit contains an SMC30 Sensor Module. An additional SMC30
Sensor Module enables safe actual value acquisition when Safety Integrated extended
functions are used.
Note
Safety Integrated Function Manual
Detailed and comprehensive instructions and information for the Safety Integrated functions
can be found in the associat
ed Function Manual. This manual is available as additional
documentation on the customer DVD supplied with the device.