EasyManua.ls Logo

Siemens SINAMICS S120 - G56, Contactor Monitoring; K01 to K05, Safety License for 1 to 5 Axes

Siemens SINAMICS S120
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Options
8.6 G56, Contactor monitoring
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
363
8.6
G56, Contactor monitoring
Availability of option
This option is available for the following S120 Cabinet Modules:
Basic Line Modules
Smart Line Modules
Active Line Modules
Description
The option is used for monitoring the pre-charging and bypass contactors of the Line
Modules.
The connecting cable from the contactors to the Control Interface Module is factory-installed.
Activation
The monitoring is activated using the following parameters:
p0255.0 = monitoring time for the pre-charging contactor (factory setting = 0, max.
6500 ms)
p0255.1 = monitoring time for the bypass contactor (factory setting = 0, max. 6500 ms)
Fault messages
F30060 (A) pre-charging contactor status monitoring
F30061 (A) bypass contactor status monitoring
8.7
K01 to K05, safety license for 1 to 5 axes
Availability of option
This option is available for the following S120 Cabinet Modules:
Booksize Cabinet Kits
Motor Modules in chassis format
Description
The Safety Integrated Basic functions do not require a license. A license is, however,
required for each axis with safety functions in the case of Safety Integrated Extended
functions. It is irrelevant which safety functions are used and how many.