EasyManua.ls Logo

Siemens SINAMICS S120 - Leds on the SMC10 Sensor Module; Leds on the SMC20 Sensor Module

Siemens SINAMICS S120
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics
7.11 LEDs on the SMC10 Sensor Module
Cabinet Modules NEMA
344 Manual, 04/2014, A5E03586450A
7.11
LEDs on the SMC10 Sensor Module
Table 7- 20 Meaning of the LEDs on the SMC10 Sensor Module
LED
Color
Status
Description
RDY
(READY)
--- Off The electronics power supply is missing or lies outside the permissible tolerance
range.
Green Continu-
ous light
The component is ready for operation and cyclic DRIVE-CLiQ communication is
taking place.
Orange Continu-
ous light
DRIVE-CLiQ communication is being established.
Red Continu-
ous light
At least one fault is present in this component.
Note:
LED is activated irrespective of any reconfiguring of the corresponding messages.
Green/
Red
Flashing
0.5 Hz
Firmware is being downloaded.
Flashing
2 Hz
Firmware download is being completed.
Waiting for POWER ON.
Green/
Orange
Or Red/
Orange
Flashing
2 Hz
Detection of the component via LED is activated (p0144).
Note:
The two options depend on the LED status when component detection is activated
via p0144 = 1.
7.12
LEDs on the SMC20 Sensor Module
Table 7- 21 Meaning of the LEDs on the SMC20 Sensor Module
LED
Color
Status
Description
RDY
(READY)
--- Off The electronics power supply is missing or lies outside the permissible tolerance
range.
Green Continu-
ous light
The component is ready for operation and cyclic DRIVE-CLiQ communication is
taking place.
Orange Continu-
ous light
DRIVE-CLiQ communication is being established.
Red Continu-
ous light
At least one fault is present in this component.
Note:
LED is activated irrespective of any reconfiguring of the corresponding messages.
Green/
Red
Flashing
0.5 Hz
Firmware is being downloaded.
Flashing
2 Hz
Firmware download is being completed.
Waiting for POWER ON.
Green/
Orange
or
Red/
Orange
Flashing Detection of the component via LED is activated (p0144).
Note:
The two options depend on the LED status when component detection is activated
via p0144 = 1.

Table of Contents