The line voltage assignments for making the appropriate setting on the transformer for the
internal power supply are indicated in the following tables.
Table 8- 15 Line voltage assignment for the internal power supply (380 to 480 V AC, 3 phase)
Adaptation transformer taps
(-T10) LH1 – LH2
431 ... 450 V 440 V 1 – 5
Table 8- 16 Line voltage assignments for the internal power supply
(500 to 690 V 3 ph. AC)
Adaptation transformer taps
(-T10) LH1 – LH2
1 to 14, terminals 12 and 13 are jumpered
1 to 15, terminals 12 and 13 are jumpered
Property damage due to voltage set too high
If the terminals are not reconnected to the actual line voltage, this can result in damage to
the device when the voltage is set too high.
• Set the terminals in accordance with the actual line voltage.