Options
8.24 L10, dv/dt filter plus Voltage Peak Limiter
Cabinet Modules NEMA
442 Manual, 04/2014, A5E03586450A
The following restrictions must be taken into account when a dV/dt filter is used:
● The output frequency is limited to no more than 150 Hz.
● Maximum permissible motor cable lengths:
– Shielded cable: Max. 980 ft (300 m) (frame sizes FX, GX, HX) / 490 ft (150 m) (frame
size JX)
– Unshielded cable: Max. 1,480 ft (450 m) (frame sizes FX, GX, HX) / 738 ft (225 m)
(frame size JX)
Table 8- 42 Maximum permissible motor cable lengths for the DC link voltage 510 - 720 V DC
Frame sizes FX, GX, HX
Shielded cable max. 980 ft (300 m) or
unshielded cable max. 1480 ft (450 m)
Frame size JX
Shielded cable max. 490 ft (150 m) or
unshielded cable max. 738 ft (225 m)
6SL3720-1TE33-8AU3 -
Table 8- 43 Maximum permissible motor cable lengths for the DC link voltage 675 - 1035 V DC
Frame sizes FX, GX, HX
Shielded cable max. 980 ft (300 m) or
unshielded cable max. 1480 ft (450 m)
Frame size JX
Shielded cable max. 490 ft (150 m) or
unshielded cable max. 738 ft (225 m)