Detailed Description   
2.7 Program operation mode 
  Mode Group, Channel, Program Operation, Reset Response (K1) 
2-92  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Event 
Part program start 
Table 2-5  Sequence when starting a part program 
Sequence  Command  Boundary conditions  
(must be satisfied before the 
command) 
Comments 
1  Channel selection: 
Reset state 
Mode selection: 
AUTO or 
AUTO and Overstore or 
MDA or 
TEACHIN 
Defined initial state: 
Channel in Reset state 
Mode: 
AUTO or 
AUTO and Overstore or 
MDA or 
TEACHIN 
Select channel and mode 
Channel: in reset status and 
mode: as per selection 
2  NC Start  None  NCK start 
3  MD20112 
$MC_START_MODE_MASK 
Initialization sequence with 
 evaluation 
Initialization sequence with 
evaluation of MD20112 
4  /_N_CMA_DIR/_N_PROG_ 
EVENT_SPF or name from 
MD11620 
As a subroutine  Implied call of the path name as 
a subroutine 
5    None  Processing of the data part of the 
main program 
6    None  Processing of the program part of 
the main program 
Event 
Part program end 
Table 2-6  Sequence at part program end 
Sequence  Command  Boundary conditions  
(must be satisfied before the 
command) 
Comments 
1  Channel selection: 
Active state 
Mode selection: 
AUTO or 
AUTO and Overstore or 
MDA or TEACHIN 
Defined initial state: 
Channel in Active state 
Mode: 
AUTO or 
AUTO and Overstore or 
MDA or TEACHIN 
Select channel and mode, 
channel: in active status and 
mode: as per selection 
2  NC Start  Block with end of part program  Block is changed 
3  MD20110 $MC_ 
RESET_MODE_MASK, 
MD20150 $MC_ 
GCODE_RESET_VALUES, 
MD20152 $MC_ 
GCODE_RESET_MODE 
Control activated: 
Reset sequence with evaluation 
Control enabled 
 Reset sequence with evaluation 
of MD 20110 and MD 20150 and 
MD 20152