2.7 Program operation mode
Mode Group, Channel, Program Operation, Reset Response (K1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-93
Sequence Command Boundary conditions
(must be satisfied before the
command)
Comments
4 /_N_CMA_DIR/_N_PROG_
EVENT_SPF or name from
MD11620
As an ASUB Implied call of the path name as
an ASUB
5 MD20110 $MC_
RESET_MODE_MASK,
MD20150 $MC_
GCODE_RESET_VALUES,
MD20152 $MC_
GCODE_RESET_MODE
Control activated:
Reset sequence with evaluation
Control activated
Reset sequence with evaluation
of MD20110 and MD20150 and
MD20152. Meaning:
The G-code indexed position
continues to be specified with
machine data
Event
Operator panel reset
Table 2-7 Sequence with operator panel reset
Sequence Command Boundary conditions
(must be satisfied before the
command)
Comments
1 Select channel and mode:
Any
Initial state: Any mode, any
channel status
Select mode/channel status from
any state
2 Reset
3 MD20110 $MC_
RESET_MODE_MASK,
MD20150 $MC_
GCODE_RESET_VALUES,
MD20152 $MC_
GCODE_RESET_MODE
Control activated:
Reset sequence with evaluation
Control activated
Reset sequence with evaluation
of MD20110 and MD20150 and
MD20152
4 /_N_CMA_DIR/_N_PROG_
EVENT_SPF or name from
MD11620
As an ASUB Implied call of the path name as
an ASUB
5 MD20110 $MC_
RESET_MODE_MASK,
MD20150 $MC_
GCODE_RESET_VALUES,
MD20152$MC_
GCODE_RESET_MODE
Control activated:
Reset sequence with evaluation
Control activated
Reset sequence with evaluation
of MD20110 and MD20150 and
MD20152. Meaning:
The G-code indexed position
continues to be specified with
machine data