Detailed Description 
  2.7 Program operation mode 
Mode Group, Channel, Program Operation, Reset Response (K1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-93 
Sequence  Command  Boundary conditions  
(must be satisfied before the 
command) 
Comments 
4  /_N_CMA_DIR/_N_PROG_ 
EVENT_SPF or name from 
MD11620 
As an ASUB  Implied call of the path name as 
an ASUB 
5  MD20110 $MC_ 
RESET_MODE_MASK, 
MD20150 $MC_ 
GCODE_RESET_VALUES, 
MD20152 $MC_ 
GCODE_RESET_MODE 
Control activated: 
Reset sequence with evaluation 
Control activated 
Reset sequence with evaluation 
of MD20110 and MD20150 and 
MD20152. Meaning: 
The G-code indexed position 
continues to be specified with 
machine data 
Event 
Operator panel reset 
Table 2-7  Sequence with operator panel reset 
Sequence  Command  Boundary conditions  
(must be satisfied before the 
command) 
Comments 
1  Select channel and mode: 
Any 
Initial state: Any mode, any 
channel status 
Select mode/channel status from
any state 
2  Reset     
3  MD20110 $MC_ 
RESET_MODE_MASK, 
MD20150 $MC_ 
GCODE_RESET_VALUES, 
MD20152 $MC_ 
GCODE_RESET_MODE 
Control activated: 
Reset sequence with evaluation 
Control activated 
Reset sequence with evaluation 
of MD20110 and MD20150 and 
MD20152 
4  /_N_CMA_DIR/_N_PROG_ 
EVENT_SPF or name from 
MD11620 
As an ASUB  Implied call of the path name as 
an ASUB 
5  MD20110 $MC_ 
RESET_MODE_MASK, 
MD20150 $MC_ 
GCODE_RESET_VALUES, 
MD20152$MC_ 
GCODE_RESET_MODE 
Control activated: 
Reset sequence with evaluation 
Control activated 
Reset sequence with evaluation 
of MD20110 and MD20150 and 
MD20152. Meaning: 
The G-code indexed position 
continues to be specified with 
machine data