Detailed Description 
  2.2 Dimensional information for transverse axes 
Transverse Axes (P1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-3 
DIAMON 
•  Display data of transverse axis in the workpiece coordinate system: 
– Setpoint and actual position 
– Distance-to-go 
– Repos offset 
•  "JOG" mode: 
– Increments for incremental dimension (INC) and travel with handwheel 
•  Part program programming: 
– End positions, independent of reference mode (G90 / G91) 
– Interpolation parameters of circular-path programming (G2 / G3) if these are 
programmed with part program instruction: AC absolute. 
•  Actual values read with reference to the workpiece coordinate system: 
– $AA_MW[
Transverse axis
] 
System variable of the measuring functions MEAS (measuring with delete distance-to-
go) and MEAW (measuring without delete distance-to-go) 
– $P_EP[
Transverse axis
] 
– $AA_IW[
Transverse axis
] 
DIAM90 
After activation of the reference-mode-dependent diameter programming, the following data 
are always displayed in relation to diameter regardless of the operating mode (G90 / G91): 
•  Actual value 
•  Actual values read with reference to the workpiece coordinate system: 
– $AA_MW[
Transverse axis
] 
System variable of the measuring functions MEAS (measuring with delete distance-to-
go) and MEAW (measuring without delete distance-to-go) 
– $P_EP[
Transverse axis
] 
– $AA_IW[
Transverse axis
]