LED response Sensor connected to responding IN
inputs
Meaning/Causes
SF-LED on cen‐
tral unit
Input LEDs on central
unit or expansion mod‐
ule
󹪞ashing red The IN LEDs of a sensor
are 󹪞ashing green.
Monitoring Universal
EMERGENCY STOP
ESPE
Protective door
Safety shutdown mat with NC prin‐
ciple
Discrepancy condition violated
For further information, see Safety ES
Two-hand operation Discrepancy condition violated
Other meanings for Advanced/
ASIsafe:
Pushbutton stuck
Do not release both pushbuttons
For further information, see Safety ES
Enabling button Discrepancy condition violated
Other meanings for Advanced/
ASIsafe:
Pushbutton stuck
For further information, see Safety ES
Protective door with lock Discrepancy condition violated
Interlock not possible because the
protective door is open
Muting functions Discrepancy condition sensor pair x
not ful󹪝lled
--
Muting functions Max. muting time exceeded
Basic: The IN LEDs of a
sensor are 󹪞ashing
green.
Advanced/ASIsafe: The
sensor that triggered the
sequence violation is
󹪞ashing green.
Monitoring Universal
Protective door
Protective door with lock
Sequence condition not ful󹪝lled
The sequence condition was not
ful󹪝lled in accordance with the pa‐
rameter assignment.
One or more IN LEDs
󹪞ashing green.
The error was detected at
this input.
Muting functions Sequence condition not ful󹪝lled
(muting)
The sequence condition was not
ful󹪝lled in accordance with the pa‐
rameter assignment.
Diagnostics / service
7.3 Diagnostics with LEDs
SIRIUS 3RK3 Modular Safety System
254 Equipment Manual, 07/2020, NEB926253002000/RS-AC/006