6.4.4.3 Menu of the DP interface
Navigation
To switch from standard mode to menu mode, choose "SET". Di󹪜erent actions can be carried out
in menu mode:
Setting the PROFIBUS address (Page 199)
Restoring factory settings (Page 201)
To switch between the sub-menus, choose "MODE". When you con󹪝rm "EXIT" with "SET", the
system switches to standard mode. When you con󹪝rm the other entries with "SET", the system
switches to the relevant sub-menu. The system also returns to standard mode after an extended
period of inactivity (30 s).
/HJHQG
$FWXDWLRQRI6(7
$FWXDWLRQRI02'(
352),%86DGGUHVV
(GLWDEOHGLJLWV
%ODQNV
5HWXUQWR
VWDWXVPRGH
5HWXUQWR
VWDWXVPRGH
3HUIRUPUHVHWWR
IDFWRU\VHWWLQJV
MENU
DP
MENU
RST
MENU
EXIT
DP
ADR
DP
xXX
DP
XxX
DP
XXx
XXX
OK
DP
EXIT
ADR
LOCK
RST
EXIT
RST
DO•
RST
LOCK
XXX
x

1) Changing the PROFIBUS address is not possible as this function has been disabled (e.g. with Safety
ES).
2) Restoring the factory settings is not possible since the DP interface is in cyclic data exchange with
a DP master.
Figure 6-19 DP interface menu
6.4.4.4 Setting the PROFIBUS address
Note
Only addresses 1 to 126 can be set. Other addresses are not possible.
Operation
6.4 Integrating into DP master systems
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006 199