4.3 Task and structure of the example
Protecting a metalworking press
The hazardous area is protected by permanent isolating protective equipment.
The insertion point is additionally protected by electrosensitive protective equipment (ESPE).
The working stroke of the press is triggered with a two-hand operator panel. If the zone
protected by the electrosensitive protective equipment is entered during operation, or if the
EMERGENCY STOP is activated, the press drive is immediately switched o󹪜 (stop category 0).
The press starts once the protective zone of the ESPE has been enabled and the two-hand
operator panel has been actuated.
Note
To enable switch-on by two-hand operation, the start pushbutton must be pressed after
unlocking the pressed EMERGENCY STOP.
Start pushbutton
Two-hand operator panel
EMERGENCY STOP control device
Light curtain (ESPE)
Figure 4-1 Typical system con󹪝guration
Getting started with MSS 3RK3 Basic
4.3 Task and structure of the example
SIRIUS 3RK3 Modular Safety System
Equipment Manual, 07/2020, NEB926253002000/RS-AC/006 63

Table of Contents

Other manuals for Siemens SIRIUS 3RK3

Related product manuals