5. Connect the module.
6. Insert the memory module with the existing conguration data.
Note
Do not connect a memory module with released conguration to a 3RK3 central unit of
another type.
The released conguration on the memory module depends on the 3RK3 central unit. For
example, the conguration released on an MSS 3RK3 Basic cannot be interpreted by an
MSS 3RK3 Advanced, or vice versa. The same applies to all other 3RK3 central units. When the
memory module is plugged into a 3RK3 central unit of another type, the conguration
release is canceled. The conguration may have to be adapted and released again.
WARNING
System restart after module replacement
Can Cause Death, Serious Injury, or Property Damage.
After the supply voltage has been applied, the new 3RK3 central unit checks whether the
expanded hardware conguration matches the device conguration. If there are no
discrepancies, the system re-enters safety mode and the safety program is executed.
Take appropriate measures (e.g. start button with monitored starting) to prevent unintentional
restarting and to ensure a dened start of the system.
Replacing expansion modules/DP interface
Note
Only replace a defective module with a module of an identical type.
1. Disconnect the defective module at the terminals.
2. Remove the defective module.
3. Install the new module.
4. Connect the module.
WARNING
System restart after module replacement
Can Cause Death, Serious Injury, or Property Damage.
After the supply voltage has been applied, the new 3RK3 central unit checks whether the
expanded hardware conguration matches the device conguration. If there are no
discrepancies, the system re-enters safety mode and the safety program is executed.
Take appropriate measures (e.g. start button with monitored starting) to prevent unintentional
restarting and to ensure a dened start of the system.
Diagnostics / service
7.9 Module replacement
SIRIUS 3RK3 Modular Safety System
350 Equipment Manual, 07/2020, NEB926253002000/RS-AC/006