Probability of a dangerous failure on demand (PFD)
1.7 x 10
-4
Characteristic values for cables
Max. permissible cable resistance 100 Ω
Max. permissible cable length from device to sensor
(for CU 1.5 mm
2
and 150 nF/km)
1000 m
(i.e., max. total cable length of 2000 m)
Max. permissible cable capacitance 330 nF
Dark period semiconductor outputs < 1 ms
AS-Interface data
AS-i voltage 18.5 V DC ... 31.6 V DC
AS-i power consumption < 45 mA
AS‑i bus load like A/B slave
AS-i slave pro󹪝les (simulated slaves)
S-7 F.F (4I/4O): standard slave (max. 4)
S-7 A.E (4I/3O): AB slave (max. 4)
S-6 B.D: safety-related output slave for controlling a
safety-related AS-i output (maximum of 12)
S-0 B.F: safety-related input slave for AS-i link (maximum
of 12)
S-7 5.5: (standard CTT2 + 2I/2O) CTT2 slave for trans‐
mission of diagnostics information (maximum of 1)
Number of devices per AS-Interface line In the maximum con󹪝guration of the AS-Interface network
in which 31 standard addresses are used, you can install up
to four additional safety monitors without addresses.
If fewer than 31 standard addresses are used, a further
monitor can be installed for each unused standard address.
If you install additional nodes without an address (e.g.,
ground fault monitoring modules), this reduces the number
of safety monitors that can be installed accordingly. When
repeaters are used, this de󹪝nition applies to each segment.
1)
The number of function elements that can be processed by one MSS 3RK3 depends on the type of function elements.
2)
Protective separation, reinforced insulation 4 kV between input circuit and output contact current paths.
3)
Time from instant an output is switched o󹪜 to the instant the output reaches a state that permits it to be switched on again.
4)
The mechanical durability may be reduced, depending on the contact load.
Technical data
8.4 3RK3 Advanced central unit
SIRIUS 3RK3 Modular Safety System
370 Equipment Manual, 07/2020, NEB926253002000/RS-AC/006

Table of Contents

Other manuals for Siemens SIRIUS 3RK3