Step Action Result
5 Connect the light curtain to the 3RK3 Basic
central unit, with
• Output 1 of the light curtain: Terminal
IN1
• Output 2 of the light curtain: Terminal
IN2
Note:
Please refer here to the operating instruc‐
tions for the light curtain.
/LJKWFXUWDLQV
7UDQVPLWWHU
5HFHLYHU
7
/0
,1,1,1 ,1
7,1 ,1,1 ,1
6 Connect the two-hand operator panel to the
3RK3 Basic central unit, with:
• NC pushbutton 1: Terminal T2/IN6
NO pushbutton 1: Terminal T1/IN5
• NC pushbutton 2: Terminal T2/IN8
NO pushbutton 2: Terminal T1/IN7
%XWWRQb
%XWWRQb
7ZRKDQGRSHUDWRUSDQHO
7
7
,1,1,1,1
,1,1,1,1
066%DVLF
'(9,&(
7 Connect the Start pushbutton on the expan‐
sion module 2/4 F‑DI 2F‑DO, with:
• NO contact: Terminal T1/IN1
6WDUW
7
7
)',)'2
,1,1
,1,1
Getting started with MSS 3RK3 Basic
4.5 Wiring of the MSS 3RK3 Basic
SIRIUS 3RK3 Modular Safety System
66 Equipment Manual, 07/2020, NEB926253002000/RS-AC/006