EasyManua.ls Logo

Siemens SIRIUS 3RK3 - Page 74

Siemens SIRIUS 3RK3
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Con󹪝guration release
Step Action Result
1 Select the menu command "Target system" > "Go o󹪜‐
line".
The o󹪠ine con󹪝guration is opened.
2 Choose "Target system" > "Approve con󹪝guration". The "Approve con󹪝guration" dialog box is opened, there‐
by con󹪝rming that the con󹪝guration test has been per‐
formed properly.
3 Set the communications interface through which you
have access to the device (e.g. COM1) and con󹪝rm with
"OK".
The "Approve con󹪝guration" dialog box opens.
4 Enter the name and approving company and con󹪝rm
with "OK".
The "Approve con󹪝guration" dialog box opens. The con‐
󹪝guration has been successfully approved.
5 Acknowledge the message with "OK". The printout of the release information is created.
Note
If the report could not be printed when the project was released, e.g. because no printer was
available, the printout must be created at the latest by the time of acceptance by selecting
"Options" > "Release information...".
Safety mode
Step Action Result
1 Establish an online connection with the MSS 3RK3 using
the "Switching device" > "Open online" or "Target system"
> "Load to PC" menu command.
The Set interface dialog box appears.
2 Set the communications interface and con󹪝rm with "OK". The project opens online.
3 Activate the menu command "Target system" > "Safety
mode".
The message "Activate safety mode" appears.
4 Con󹪝rm with "Yes". The MSS 3RK3 switches to safety mode without pass‐
word protection.
Getting started with MSS 3RK3 Basic
4.8 Function test of the MSS 3RK3 Basic
SIRIUS 3RK3 Modular Safety System
74 Equipment Manual, 07/2020, NEB926253002000/RS-AC/006