Functions
7.12 Reflexor
FUE1010 IP65 NEMA 4X
136 Operating Instructions, 12/2014, A5E03086491-AC
The Spectra Graph display shows the results of the Fast Fourier Transform (FFT) performed
by the flow meter.
The horizontal scale represents flow velocity with the higher velocities on the right and
lower velocities on the left.
The vertical axis is relative amplitude or magnitude; each bar shows the relative
amplitude for a velocity range.
Meter Type
Flow Velocity Range
Measurement Channel
Noise Level Set Cursor
Site Name
Low Limit Cursor
High Limit Cursor
Signal Amplitude
Figure 7-4 Spectra Graph Display Screen
The reported flow rate is the mean value of the included Spectra Graph bars. It is computed
by excluding signals that are lower (to the left of) than the Low Limit Cursor or higher (to the
right of) than the High Flow Cursor or lower (under) than the Noise Cursor.