Functions
7.1 Selecting Flow Units
FUE1010 IP65 NEMA 4X
98 Operating Instructions, 12/2014, A5E03086491-AC
5. Press the <Right Arrow> to select [Energy Units].
6. Press the <Right Arrow> to select the option list and use the <Up/Down Arrows> to select
the desired units.
7. Press <ENTER> to store selection.
The Totalizer function operates in any of the modes listed below:
Table 7- 1 Totalizer Modes
POSFLOW positive flow Accumulates flow in positive
NEGFLOW negative flow Accumulates flow in reverse
NETFLOW positive or negative flow Adds to positive total; subtracts
from reverse total