Functions
7.1 Selecting Flow Units
FUE1010 IP65 NEMA 4X
98 Operating Instructions, 12/2014, A5E03086491-AC
5. Press the <Right Arrow> to select [Energy Units].
6. Press the <Right Arrow> to select the option list and use the <Up/Down Arrows> to select
the desired units.
7. Press <ENTER> to store selection.
Totalizer Modes
The Totalizer function operates in any of the modes listed below:
Table 7- 1 Totalizer Modes
Mode
Flow Direction
Notes
POSFLOW positive flow Accumulates flow in positive
direction only
NEGFLOW negative flow Accumulates flow in reverse
direction only
NETFLOW positive or negative flow Adds to positive total; subtracts
from reverse total