Installation safety precautions
In applications with working pressures/media that can be dangerous to people,
surroundings, equipment or others in case of pipe fracture, we recommend that special
precautions such as special placement, shielding or installation of a security guard or a
security valve are taken when the sensor is mounted.
● Ensure that stresses and loading caused by e.g. earthquakes, traffic, high winds and fire
damage if appropriate are taken into account during installation.
● Ensure that the flowmeter is installed such that it does not act as a focus for pipeline
stresses. External loadings are not taken into account in the flowmeter design.
● Provide adequate protection to minimise any risk of contact with hot surfaces.
Prevent personal injuries by assuring that operation below pressure guards cannot take
place, if working with vacuum or fluids boiling readily.
May cause death or serious personal injury.
Disconnect power before working on this product.
● Avoid long drop lines downstream from the sensor to prevent the meter pipe from
draining.
● Avoid installing the sensor upstream of a free discharge in a drop line where possible.