Troubleshooting
10.3 Test Facilities Graph Screen
FUE1010 IP65 NEMA 4X
Operating Instructions, 12/2014, A5E03086491-AC
161
<7> MaskSet Leading edge masking functions (use +
or - to alter number of samples
<8> Hold Set Set this number higher if intermittent
mis-registration occurs.
<=> Toggle graph between receive wave-
form and envelope waveform.
Downloading Signal Graph Data
DP n Command
To download the Signal Graph data use either the Si-Ware or Windows HyperTerminal
program.
Note
Si-Ware
The following Signal Graph Data download procedure uses the Si
-Ware program.
1. Open Si-Ware and select [Terminal Mode].
2. To start Signal Data Graph download: Type: DP<Space><Path #>. For example: DP 1.
3. Import downloaded Signal Graph data to MS Excel.
4. Select [Space] delimited Data in the Text Import Wizard to distribute data in columns.
5. Use the Excel Chart Wizard to graph columns 2 and 3 and produce the Signal Graph.