Communication via CAN bus (CANopen)
AP10
Date: 28.02.2022 Art. No. 86853 Mod. status 37/22 Page 41 of 78
Sub-index
03h
Description
reset only application parameters to factory settings
Access
rw
PDO mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 1
0, reserved
Bit 0
1: unit permits loading of default parameters
Sub-index
04h
Description
reset only manufacturer-specific parameters to factory settings
Access
rw
PDO mapping
no
Data type
UNSIGNED 32
Default
1h
EEPROM
no
Data content
Write:
Byte 0
Byte 1
Byte 2
Byte 3
6Ch ("l")
6Fh ("o")
61h ("a")
64h ("d")
Read:
Bit 31 1
0, reserved
Bit 0
1: unit permits loading of default parameters