EasyManuals Logo

Siko AP10 User Manual

Siko AP10
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
Communication via CAN bus (CANopen)
AP10
Date: 28.02.2022 Art. No. 86853 Mod. status 37/22 Page 65 of 78
5.7.2.40 5F14h: Loop length
Object 5F14h specifies the loop length by which the set point shall be moved over with loop
travel (see chapter 4.1.1.2).
Sub-index
00h
Description
loop length
Access
rw
PDO mapping
no
Data type
UNSIGNED 16
Default
0h
EEPROM
yes
Data content
0 9999
5.7.2.41 5F15h: Positioning type
The positioning type, loop type is indicated via object 5F15h, thereby selecting the direction
from which the set point shall be approached (see chapter 4.1.1.2).
Sub-index
00h
Description
Set point is approached in this direction.
Access
rw
PDO mapping
no
Data type
UNSIGNED 8
Default
0h
EEPROM
yes
Data content
0: no loop
1: loop +
2: loop -
5.7.2.42 5F16h: Read target value
The current set points can be read via object 5F16h.
Sub-index
00h
Description
indicates the largest sub-index supported
Access
ro
PDO mapping
no
Data type
UNSIGNED 8
Default
4h
EEPROM
no

Table of Contents