Page 60 SIMPLEX 4100 EWIS
INSTALLATION MANUAL
Document No.: 4100-M011 March 1998 Issue 1.0
4.9 Point List Summary
The Point List Summary identifies the number of pseudo lists within the system.
These lists are in numerical sequence, contain a description, and identify the number
of points within each list.
--------------------------------------------------------------------------------
XYZ BUILDING POINT LIST SUMMARY Page 31
2796 node:1 rev:6 14:41:55, WED, 25-MAR-98
--------------------------------------------------------------------------------
CARD No: 160 POINT LIST
256 Point List Pseudo L86 - L145
continued
List Name Description Points
--------- ---------------------------------------- ------
L86 RESTART MESSAGE AFTER MIKE - VTG 2 EMPTY
L87 AHU RELAYS ON - ON FIRE ALARM EMPTY
L88 AHU RELAYS OFF - ON FIRE ALARM EMPTY
L89 AHU RELAYS OFF - ON SYSTEM RESET EMPTY
L90 ALL SPEAKERS - NON EDITABLE EMPTY
L91 AUDIO CODING GROUP 1 - SIGNAL CIRCUITS EMPTY
L92 AUDIO CODING GROUP 2 - SIGNAL CIRCUITS EMPTY
L93 PHONE CIRCUITS 30
L94 REMOTE MASTER PHONE CIRCUITS EMPTY
L95 SATELLITE PHONES - SCC 4100 ON/OFF EMPTY
L96 SATELLITE PHONES - SCC 4100 NORMAL/SHORT EMPTY
L97 SATELLITE PHONES - SCC 4100 ON/OFF RMPH EMPTY
L98 SWITCH POWER SUPPLY AMPS TO BATTERY 2
L99 SWITCH POWER SUPPLY AMPS TO BKGRND MUSIC 2
L100 POINTS TO EXCLUDE FROM AUTOMAP EMPTY
L101 RESET POWER SUPPLY AMPS 2
L102 LISTS TO AUTO-GENERATE EXTERNAL POINTS 21
L103 EXTERNAL DETECTOR RESET PSEUDO EMPTY
L104 EXTERNAL SYSTEM RESET PSEUDO EMPTY
L105 EXTERNAL DETECTOR/SYSTEM RESET PSEUDO EMPTY
L106 EXTERNAL SIGNAL SILENCE PSEUDO EMPTY
L107 ENTER LOCAL MODE ON DATA NOT AVAILABLE EMPTY
L108 EXTERNAL SPEAKERS AND SPEAKER LISTS EMPTY
L109 ALARM SILENCED LED CONTROL EMPTY
L112 EXTERNAL PRIORITY 2 RESET PSEUDOS EMPTY
L128 BRIGADE ALARM 1 LIST (PFA) EMPTY
L129 BRIGADE ALARM 2 LIST (VMD) EMPTY
L130 AMP 1 FIRE TRIP LIST 1
L131 AMP 2 FIRE TRIP LIST 1
L132 AMP 3 FIRE TRIP LIST 1
L133 AMP 4 FIRE TRIP LIST 1
L134 AMP 5 FIRE TRIP LIST 1
L135 AMP 6 FIRE TRIP LIST 1
L136 AMP 7 FIRE TRIP LIST 1
L137 AMP 8 FIRE TRIP LIST 1
L138 AMP 9 FIRE TRIP LIST 1
L139 AMP 10 FIRE TRIP LIST 1
L140 AMP 11 FIRE TRIP LIST 1
L141 AMP 12 FIRE TRIP LIST 1
L142 AMP 13 FIRE TRIP LIST 1
L143 AMP 14 FIRE TRIP LIST 1
L144 AMP 15 FIRE TRIP LIST 1
L145 AMP 16 FIRE TRIP LIST 1
NOTE: * Indicates Auto List Generation disabled for system list.
Table 13 POINT LIST SUMMARY

Table of Contents

Other manuals for Simplex 4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex 4100 and is the answer not in the manual?

Simplex 4100 Specifications

General IconGeneral
TypeFire Alarm Control Panel
ManufacturerSimplex
Model4100
Network CapabilityYes
AddressableYes
Power Supply120/240 VAC, 50/60 Hz
DisplayLCD
Annunciator SupportYes
Battery BackupYes
Releasing CapabilityYes
Max DevicesDepends on configuration
Max Notification Appliance Circuits (NAC)Varies with configuration
Max Releasing CircuitsVaries with configuration
Max Remote AnnunciatorsVaries with configuration
Communication PortsMultiple
Operating Temperature32°F to 120°F (0°C to 49°C)
Humidity RangeUp to 93% RH, non-condensing
NAC Outputs4 (expandable)
NetworkingYes

Related product manuals