EasyManua.ls Logo

Simplex 4100 - Entering and Exiting Walk Test Mode

Simplex 4100
97 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 62 SIMPLEX 4100 EWIS
INSTALLATION MANUAL
Document No.: 4100-M011 March 1998 Issue 1.0
4.11 OPTIONS DETAIL REPORT
The Options Detail Report specifies the options selected for the system. Also
included in this report is a list of the passcode assignment levels for the various
system functions.
--------------------------------------------------------------------------------
XYZ BUILDING OPTIONS DETAIL REPORT Page 99
2796 node:1 rev:6 14:41:55, WED, 25-MAR-98
--------------------------------------------------------------------------------
OPTIONS
PASSCODES
Protection
Display Function Level
---------------------------------------- ----------
Alarm Silence 1
System Reset 1
Change Time and Date 1
Panel Control Key 1 1
Panel Control Key 2 1
Panel Control Key 3 1
Panel Control Key 4 1
Panel Control Key 5 1
ON/OFF/AUTO Keys 1
ARM/DISARM Keys 1
Change TrueAlarm Sensitivities 3
DISABLE/ENABLE Keys 3
Clear Trouble Log 3
Clear Alarm Log 3
Enter/exit Walk Test mode 3
Clear Alarm Verification tallies 3
* Fire Alarm Acknowledge 1
* Priority 2 Acknowledge 1
* Supervisory Acknowledge 1
* Trouble Acknowledge 1
* Alarm List/Display Time 1
* Change Point Status 4
* Run Diagnostics 4
* Display Diagnostics 3
* Remote Download 4
* Display Idle Time 4
* Memory Access 4
NOTE: * Indicates protected functions not on order sheet.
PROTECTION SCALE
Level 1 - Lo
Level 4 - Hi
Table 15 OPTIONS DETAIL REPORT

Table of Contents

Other manuals for Simplex 4100

Related product manuals