Page #192 background imageLoading...
Page #192 background image
184
Operation on LCD
Setting Battery Heating
Battery heating setting is used to restore the charging and discharging function
of the battery in a low temperature environment. This function works when the
battery connected supports battery heating.
Set Enable to define the battery heating periods as follows. If the battery does not
support this function, then set it Disable.
===Battery Heating===
Heating Period 1
End Time
00:00
===Battery Heating===
Heating Period 2
Start Time
00:00
===Battery Heating===
Heating Period 2
End Time
00:00
===Battery Heating===
Func Select:
> Enable <
===Battery Heating===
Heating Period 1
Start Time
00:00
Figure 9-92 Enabling battery heating and setting working periods
Setting Extended BAT FUNC
This function is for averaging the capacity of every battery before battery
expansion. This setting shall be invalid under the EPS mode. When it is on-grid,
enabling this setting shall make the inverter charge or discharge the battery SoC
to about 40%, which is convenient for adding new batteries.
===Extend BAT FUNC===
Function Control
> Enable <
Figure 9-93 Enabling/ disabling battery expansion function
Setting Hotstandby Setting
Enable is the default setting. The inverter cannot enter standby status when
Disable is set.
==HotStandby Setting==
Function Control
> Enable <
Figure 9-94 Enabling/ disabling hotstandby function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-IES Series and is the answer not in the manual?

SolaX Power X3-IES Series Specifications

General IconGeneral
BrandSolaX Power
ModelX3-IES Series
CategoryInverter
LanguageEnglish

Related product manuals