196
Troubleshooting and Maintenance
Error Code Fault Descriptions and Diagnosis
IE 111 ARM ParaCom FIt
ARMParaComFIt
Please check that the communication cables of
inverters are well connected and the baud rate of
COMM setting of inverters are the same.
Or seek help from the installer if it can not return to
normal.
IE 112 FAN1 Fault
FAN1 Fault
Please change the fan.
Or seek help from the installer if it can not return to
normal.
IE113 FAN2 Fault
FAN2 Fault
Please change the fan.
Or seek help from the installer if it can not return to
normal.
BE 01 BMS_ExterErr
Battery Error - External Communication Fault
Please contact the battery supplier.
BE 02 BMS_InterErr
Internal fault of BMS.
Unable to establish communication among battery
modules.
Restart the BMS.
Check whether the wire connections among
battery modules are correct.
Contact the after-sales personnel of our company.
BE 03 BMS_OverVolt
BMS overvoltage
Overvoltage of a single battery module.
Contact the after-sales personnel of our company.
BE 04 BMS_LowerVolt
BMS undervoltage
Undervoltage of a single battery module.
Battery module is forced to charge through
inverter.
Contact the after-sales personnel of our company.
BE 05 BMS_ChargeOCP
Overcurrent charging of BMS.
Restart the BMS.
Contact the after-sales personnel of our company.
BE 06 DischargeOCP
Discharge overcurrent of BMS.
Restart the BMS.
Contact the after-sales personnel of our company.
BE 07 BMS_TemHigh
The temperature of the BMS is too high.
Cool down the BMS to normal temperature, and
then restart it.
Contact the after-sales personnel of our company.