EasyManuals Logo

Spectra Precision FOCUS 2 Series User Manual

Spectra Precision FOCUS 2 Series
159 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
SPECTRA PRECISION FOCUS 2 SERIES TOTAL STATION USER GUIDE
6 – Menu Key
118
Station records
Viewing records by station
1. From the Data menu, press [3] (or press [v] and [REC/ENT])
to select ST
SS/SO/CP.
The Stn Data screen appears.
2. Press [^] or [v] to scroll through the list.
3. To view detailed information about the selected station,
press
[REC/ENT]. Press [ESC] to return to the list.
4. To display all the observation data from the selected
station, press
[REC/ENT] again.
Note – Detailed data is as for raw data. For detailed information about each point type and format,
see
RAW data, page 112.
Deleting station records
1. In the Stn Data screen (or in the data screen that appears when you press [REC/ENT]), press [^] or [v]
to highlight the record to be deleted. Then press the
DEL softkey.
2. A confirmation screen appears. Press [REC/ENT] or the OK softkey to delete the selected record.
(Otherwise, press the
CE softkey.)
3. A reconfirmation screen appears. Press the OK softkey to delete the selected record. (Otherwise,
press the
CE softkey.)
Editing station records
The system will not recalculate measurements if the station record is changed—this means that the
current station cannot be edited.
1. In the Stn Data screen (or in the data screen that appears when [REC/ENT] is pressed), press [^] or
[v] to highlight the record to be edited. Then press the Edit softkey.
2. Enter the new data manually or select data using the List or Stac softkey and then press
[REC/ENT].
3. To rewrite the data, press [REC/ENT] or the OK softkey. (Otherwise, press the CE softkey.)
The system executes the operation and returns to the RAW Data screen.
Note – If the station (ST) or instrument height (HI) values are changed, the coordinates of observation
points are not recalculated. If the BS or AZ values are changed, raw records are not recalculated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectra Precision FOCUS 2 Series and is the answer not in the manual?

Spectra Precision FOCUS 2 Series Specifications

General IconGeneral
BrandSpectra Precision
ModelFOCUS 2 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals