Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
137
Please connect ‘J1’in the control board with wire jumper before group controlling so as to bridge
terminal resistor of two serial communication wire TXA+ , TXA-.
3Measurement of resistance
After setting the wire jumpers, please use an universal meter to measure the value of the terminal
resistance for the future commissioning.
The resistance value of JP5.4 and JP5.5 in the main control board is about 60ohm, if the value is
not within this limit, please check the wire jumper is in position or not, the shielded cable is good
and plug in the control board is reliable.
4Manu Setting
Before debugging the group-control system, please make sure that each and every elevator is in
normal state, then link to the group control system and start the system commissioning by setting
Parameter “Group Mode” of all the elevators to 2 firstly.
6.7.10 Instruction for the group-control parameter setting programming
1 Basic instruction
This program is used for setting the parameter in the group-control CPU board. Connecting
computer and group-control CPU board with standard RS232 communication wire set the
parameter in computer. The DC5V power supply must be connected to the group control CPU
board when in operation. Please take reference to the connection diagram of group control board
for the wiring.
2 Installation of program
This program can run directly from CD without installation, or copy to the any folder in an pc for
running. In the CD Rom we supplied for client, there are two files GROUPSET.EXE and
MSCOMM32.OCX. GROUPSET.EXE is a setting file and MSCOMM32.OCX is a control file. If
in your computer there is not file MSCOMM32.OCX, file GROUPSET.EXE is not able to run
correctly.
Please do following steps to setup MSCOMM32.OCX:
Copy file Mscomm32.ocx form CD Rom to directory SYSTEM of Windows in your computer,
open Run Dialog, click browsing button, select file Regsvr32.exe in the directory SYSTEM of
Windows, click Open button, input MScomm32.ocx after Regsvr32.exe and click OK button, then
run register program. After running the program a dialogue box displays, click OK button and
restart the monitor program.
This program demands the display resolution of your computer to 1024*768
3 Running the setting program
Double click the file GROUPSET.EXE, the main interface of the program is displayed. click Set
Button to enter the parameter-setting interface.