Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
161
is set as zero, the corresponding floor should be set as non-service floor with no parking
allowed. The non-service floor with no parking allowed can not register call. The
parameter in operator is set floor by floorone bit after anotherduring the actual
operation. Therefore there is no need to calculate the value.
F30—— service floor 2, F30 value set whether the actual floor sequence from 17th to 32nd is
allowed to park or not. It is 16 bit data. The bottom bit for the 17
th
floor, the ceiling bit
for 32nd floors. When any point within that range is set as one, the corresponding floor
should be set as service floor for parking. Vice versa, when any point within that range
is set as zero, the corresponding floor should be set as non-service floor with no parking
allowed. The non-service floor with no parking allowed can not register call. The
parameter in operator is set floor by floorone bit after anotherduring the actual
operation. Therefore there is no need to calculate the value.
F31—— service floor 3, F31 value set whether the actual floor sequence from 33rd to 48th is
allowed to park or not. It is 16 bit data. The bottom bit for the 33
rd
floor, the ceiling bit
for 48th floors. When any point within that range is set as one, the corresponding floor
should be set as service floor for parking. Vice versa, when any point within that range
is set as zero, the corresponding floor should be set as non-service floor with no parking
allowed. The non-service floor with no parking allowed can not register call. The
parameter in operator is set floor by floorone bit after anotherduring the actual
operation. Therefore there is no need to calculate the value.
F190——service floor 4, F190 value set whether the actual floor sequence from 49th to 64th is
allowed to park or not. It is 16 bit data. The bottom bit for the 49
th
floor, the ceiling bit
for 64th floors. When any point within that range is set as one, the corresponding floor
should be set as service floor for parking. Vice versa, when any point within that range
is set as zero, the corresponding floor should be set as non-service floor with no parking
allowed. The non-service floor with no parking allowed can not register call. The
parameter in operator is set floor by floorone bit after anotherduring the actual
operation. Therefore there is no need to calculate the value.
the setting of service-floor (floor blocking) can also be controlled on group control panel
within group control. The floor sequence should be arranged in accordance with the
floor sequence of the whole elevator group if the group is in group control or parallel
connection.
F33—— the time interval between the running testing startup and auto running. The default value
is 5 seconds
F34—— the auto running times after running testing startup. The default value is 0, which means
the deactivation of running testing function in elevator.
Note: The two values of F33 and F34 is set for the elevator running test. Once the F33 and F34
are set, tester can use handheld operator or control wheel to register call and the elevator
will run automatically among the registered floor until the defined times set by F34
F35—— definition of firefighting switch input point and firefighting mode selection.
Among which:
Bit 0 set as 1: Schindler firefighting mode.
Bit 0 set as 0: common firefighting mode.
Bit 1 set as 1: activate firefighting switch input of car board.