AS380 Series Elevator Integrated Drive Controller
163
starting the mode 1 and mode 2 self studies.
F43—— landing call buzzing/flashing and door-closing standby option when in attendant status.
This parameter is only valid in attendant status.
Among which:
Bit0 set as 1, buzzing inside car when pressing call button
Bit0 set as 0, no buzzing inside car when pressing call button.
Bit1 set as 1, the corresponding inductor button inside car flash to the floor with call
registration.
Bit1 set as 0, no flashing inductor button in car
Bit2 set as 1, door-closing and standby allowed in attendant status.
Bit2 set as 0, door-closing and standby not allowed in attendant status
Bit3 set as 1, schindler attendant mode
Bit3 set as 0, common attendant mode
When users set the parameter F43 on the handheld operator, it will guide the users to set
the parameter bit by bit (function by function) instead of calculating and setting all in
one time.
F44——local address of serial communication, the value of elevator running or single elevator
monitoring is set to 255. If the port 485 community monitoring or port 232 remote
monitoring is applied to banks, every elevator in the bank can be set one of natural
number smaller than 255 for the main board identification by remote PC. Therefore
every elevator in the bank can have independent setting.
F49—— Emergency leveling orientation mode,
0: judge return leveling orientation through pretorque. If the pretorque is less than 0,
return leveling turns upward.
1: judge return leveling orientation through pretorque. If the pretorque is less than 0,
return leveling turns downward.
2: use weighing compensation value to judge the return leveling orientation.
F50—— front door opening allowed. 1. Setting whether the floor 1-16 (floor sequence) allowed
opening or not. The lowest position corresponds to the front door of the lowest floor.
The highest position corresponds to the front door of 16
th
floor counting from the lowest
floor.
F51—— front door opening allowed. 2. Setting whether the floor 17-32 (floor sequence) allowed
opening or not. The lowest position corresponds to the front door of the 17th floor. The
highest position corresponds to the front door of 32
nd
floor
F52—— front door opening allowed. 3. Setting whether the floor 33-48 (floor sequence) allowed
opening or not. The lowest position corresponds to the front door of the 33rd floor. The
highest position corresponds to the front door of 48
th
floor
F191——front door opening allowed. 4. Setting whether the floor 49-64 (floor sequence) allowed
opening or not. The lowest position corresponds to the front door of the 49th floor. The
highest position corresponds to the front door of 64th floor
F53—— rear door opening allowed. 1. Setting whether the floor 1-16 (floor sequence) allowed
opening or not. The lowest position corresponds to the rear door of the lowest floor. The
highest position corresponds to the rear door of 16
th
floor counting from the lowest
floor.