Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
171
Note 2:
F193 is the bottom floor non-load compensation adjusting parameter when the
elevator pre-load compensation function started up. Namely: when the elevator is
non-loaded at the bottom floor, the required compensation load set by F193 will make
the elevator startup in best condition.
F194 is the bottom-floor full-load compensation adjustable parameter,
F195 is the top-floor non-load compensation adjustable parameter.
On detailed adjusting method of above three parameters, please take reference
to the section 8, 10 of chapter 8 ( the detailed introduction about adjusting method of
the elevator startup pre-load compensation function)
F196—— 2
nd
homing base station when in parallel connection
F200—— frequency converter version number. It is the default read-only data.
F201—— frequency converter control mode.
If need to motify, first set F244=2345, then set F201. After
powering-down and
powering-up again, F201 is 3 automaticly.
0: none- speed sensor V/f control mode.
1: none-speed sensor vector control mode. 2: speed sensor torque control mode. 3:
speed sensor vector control mode. The default is 3. The speed sensor vector control
mode is usually adopted in formal use. Therefore the default parameter is 3. However,
the parameter can be set as 0 for time being to run the frequency converter in open
loop V/F control mode at some adjusting &setting situation so that the car can be
moved before the encoder installed.
Please note: before preparing hoist way self-study, it is necessary to install the
encoder, complete the wiring, and reset the F201 to 3.
F202—— motor type selection. 0: asynchronous, 1: synchronous
F203—— motor rated power, the unit is KW, set in accordance with nameplate
F204—— motor rated current, the unit is A , set in accordance with nameplate
F205—— motor rated frequency, the unit is Hz, set in accordance with nameplate
F206—— motor rated revolution, the unit is rpm. Set in accordance with nameplate
F207—— motor rated voltage, the unit is V. Set in accordance with nameplate.
F208—— motor poles number, set in accordance with nameplate. If no poles number is shown on
the nameplate, please take reference to the following formula.
The NO. of poles=120×f÷n. In the formula: n—rated revolution; f –rated frequency.
For the calculated result, the even-integral number is adopted as poles number.
F209——motor rated slip frequency. The unit is Hz. Only be effective for asynchronous motor.
Set in accordance with nameplate. If the rated slip frequency is not shown on the
nameplate, please take reference to the following formula for F209 setting value.
Rated frequency—F (F205), Rated revolution—N (F206), motor poles No. (F208)
Slip frequency= f-(n×p÷120
For example: the rated frequency-50Hz, the rated revolution-1430rpm, the motor pole
No-4
F209 setting value= 50-(1430×4÷120)=2.33Hz
F210——encoder type. 0: increment encoder, 1: sin/cos encoder. 2: Endat encoder
F211——encoder pulse No. Per circle . The unit is Ppr