Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
247
F163 Choose whether the
back-up power continues
running after returning to
the base in case of single
elevator or parallel
connection
0 0/1
×
0: stop running
1: may continue
running
F164 Type of weighing device 99 0~99 ×
See the manual for
more detailed
explanation
F165 Special control of door
operation
0 0~65535 × Bit0: 1: door closed
during Ispection
Bit1: 1: door closed
during debug running
Bit2: 1: door opened
at the base station for
the elevator
Bit3: 1: whether to
open the door by LED
operator
F168 Elevator No. with IC card
service
0 0~65535 ×
F169 Selection of upward and
downward callus by IC
card
0 0~65535 ×
F170 IC card function in the car
corresponding to IC card
swiping need on Floor 1~
16
0 0~65535 ×
F171 IC card function in the car
corresponding to IC card
swiping need on Floor
17~32
0 0~65535 ×
F172 IC card function in the car
corresponding to IC card
swiping need on Floor
33~48
0 0~65535 ×
F175 Creeping speed at startup 0.006 0~0.100 m/s
F180 Speed gain 100.0 0~110.0 %
F181 Elevator No. at mutual
parallel connection mode
0 0~1 ×