Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
246
F133
Time section floor
blockade closure time set
0 0-65535
F137 Service floor 1 (Floor 1~
16) when NS-SW function
is set.
65535 0~65535 ×
F138 Service floor 2 (Floor 17~
32) when NS-SW function
is set.
65535 0~65535 ×
F139 Service floor 3 (Floor 33~
48) when NS-SW function
is set.
65535 0~65535 ×
F199 Service floor 4 (Floor 49~
64) when NS-SW function
is set.
65535 0~65535 ×
F141 Time of delay release of
the main contactor (after
enabled)
0.50 0.50~10.00 s
F145 Bus voltage gain 100 80~120 %
F146 Position error distance 180 180~1000 mm
F147
Protection of contact
detection
0 0~1
F152 Lighting delay (fans turned
off automatically, delay
lighting)
180 0~65535 S 0: do not turn off the
lights
F153 high-voltage input
detection with or without
hall door lock
1 0/1 × 0: No
1: Yes
F156 With or without lock relay
contact detection
1 0/1 × 0: No
1: Yes
F160 Whether the manual
removal of error
instruction activated
1 0/1 × 0: No
1: Yes
F161
The function of floor
blocking for a time slot
0 0~65535
× Bit0: 1: block
instruction
Bit1: 1: block upward
call
Bit2: 1: block
downward call