F74 Light load height gain
512 0-1024
F75 Heavy load height gain
512 0-1024
F115 Overtime opening door 15 3~30 s
F116 Overtime closing door 15 3~30 s
F117 Opening time for forced
closing
60 0~1800 s
F118 Opening time for the
disabled
10 0~1800 s
F120 Car call number when
anti-nuisance function
activates.
0 0~30 ×
F121 Activate forced closing
function (0 represents not
activate)
0 0~1 ×
F122 Signal delay release time
in Inspection.
0.3 0~10.0 s
F123 Call categories 0 0~3 x
F124 Define the function of
mainboard X16 input point
0 0~2 ×
F128 Control of front and rear
doors
0 0/1 × 0: separate control of
front and back doors;
1: joint control of
front and back doors
F129 Activate the functions of
re-leveling and/or
pre-opening
0 0~3 ×
F130
Maintain the
opening/closing torque
0 0~7
× Bit0: 1: door
maintaining open
Bit1: 1: door
maintaining closed
Bit2: 1: door
maintaining closed
during operation
F131
Time section floor
blockade floor set
0 0-65535
F132 Time section floor
blockade beginning time
set
0 0-65535