EasyManua.ls Logo

Stober SI6A062 - X4 B: Encoder B; X9: Ethernet Service Interface; Tab. 109 X9 Connection Description; Tab. 110 Cable Length [M]

Stober SI6A062
264 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | Connection STOBER
124
02/2019 | ID 442728.05
10.5.7 X4B: Encoder B
The encoder of axis B is connected to X4B for double-axis controllers. Only X4A is available for
single-axis controllers. The connection description of X4B matches the X4A description.
10.5.8 X9: Ethernet service interface
X9 is used to connect the drive controller to a PC with installed DriveControlSuite
commissioning software.
Socket Pin Designation Function
1|2|3|4|5|6|7|8 1 TxData+ Ethernet communication
2 TxData−
3 RecvData+
4
5
6 RecvData− Ethernet communication
7
8
Tab. 109: X9 connection description
Cable requirements
Feature All sizes
Max. cable length 100m, shielded
Tab. 110: Cable length [m]
Information
To ensure proper functionality, we recommend using cables from STOBER that are matched to
the complete system. In case of use of unsuitable connection cables, we reserve the right to
reject claims under the warranty.
It is also possible to use cables with the following specification:
Feature Design
Connector wiring Patch or crossover
Quality CAT 5e
Shielding SF/FTP, S/FTP or SF/UTP
Tab. 111: Cable requirements
Device addressing
Information for device addressing can be found in the chapter Device addressing [}242].

Table of Contents

Related product manuals