16 | Appendix STOBER
234
02/2019 | ID 442728.05
16.1.5 BLDF 5.08 180 SN
Feature Line type Value
Contact spacing — 5.08mm
Nominal current at ϑ
amb
= 40°C — CE/UL/CSA:
14A/10A/10A
Max. conductor cross-section Flexible without end sleeve 2.5mm²
Flexible with end sleeve without plastic collar 2.5mm²
Flexible with end sleeve with plastic collar 2.5mm²
2 conductors, flexible, with double end sleeve
with plastic collar
—
AWG according to UL/CSA 12
Min. conductor cross-section Flexible without end sleeve 0.2mm²
Flexible with end sleeve without plastic collar 0.2mm²
Flexible with end sleeve with plastic collar 0.25mm²
2 conductors, flexible, with double end sleeve
with plastic collar
—
AWG according to UL/CSA 26
Insulation stripping length — 10mm
Tightening torque — —
Tab. 231: BLDF 5.08 180 SN specification
16.1.6 FKC 2,5 -ST-5,08
Feature Line type Value
Contact spacing — 5.08mm
Nominal current at ϑ
amb
= 40°C — CE/UL/CSA:
12A/10A/10A
Max. conductor cross-section Flexible without end sleeve 2.5mm²
Flexible with end sleeve without plastic collar 2.5mm²
Flexible with end sleeve with plastic collar 2.5mm²
2 conductors, flexible, with double end sleeve
with plastic collar
1.0mm²
AWG according to UL/CSA 12
Min. conductor cross-section Flexible without end sleeve 0.2mm²
Flexible with end sleeve without plastic collar 0.25mm²
Flexible with end sleeve with plastic collar 0.25mm²
2 conductors, flexible, with double end sleeve
with plastic collar
0.5mm²
AWG according to UL/CSA 26
Insulation stripping length — 10mm
Tightening torque — —
Tab. 232: Specification for FKC 2,5 -ST-5,08