R6,Technical Data
101
14 TechnicalData
14.1 AngleMeasurement
Accuracy
Characteristics
Absolute,continuous,diametric.Updateseach0.1to0.3 s.
14.2 DistanceMeasurementwithReflectors
Range
Atmosphericconditions
Accuracy
Accuracyreferstomeasurementstostandardreflectors.
Available
angularaccu
racies
Standarddeviation
HA,VA,ISO 171233
Displayresolution
["] [mgon] ["] [°] [mgon] [mil]
2 0.6 1 0.0001 0.1 0.01
3 1.0 1 0.0001 0.1 0.01
5 1.5 1 0.0001 0.1 0.01
7 2 1 0.0001 0.1 0.01
Reflector RangeA RangeB RangeC
[m] [ft] [m] [ft] [m] [ft]
Standardprism 1800 6000 3000 10000 3500 12000
3prisms 2300 7500 4500 14700 5400 17700
Reflectorfoil
60 mmx60 mm
150 500 250 800 250 800
Shortestmeasuringdistance: 1.5 m
RangeA: Stronghaze,visibility5 km;orstrongsunlight,severeheatshimmer
RangeB: Lighthaze,visibilityabout20 km;ormoderatesunlight,slightheatshimmer
RangeC: Overcast,nohaze,visibilityabout40 km;noheatshimmer