R6,Applications
62
MISSINGLINERESULTPolygonalmethod
Nextstep
PressESCtoexittheapplication.
9.7 Resection
9.7.1 StartingResection
Description
Resectionisanapplicationusedtodeterminetheinstrumentspositionfrommeasurementsto
knownpoints.Aminimumoftwoknownpointsandamaximumof5,canbeusedtodetermine
theposition.
Access
1) SelectAppsfromtheMAIN MENU.
2) SelectResectionfromtheAPPSmenu.
3) Completeapplicationpre‐settings.Referto"8Applications‐GettingStarted".
4) Select Accuracy Limit:
NewPt 1
Tocalculateanadditionalline.Applicationstarts
againatpoint1.
NewPt 2
Tosetpoint2asthestartingpointofanewline.A
newpoint2mustbemeasured.
RADIAL
Toswitchtoradialmethod.
Field Description
Grade Grade[%]betweenpoint1andpoint2.
d.S.D Slopedistancebetweenpoint1andpoint2.
d.H.D Horizontaldistancebetweenpoint1andpoint2.
d.d.Z Heightdifferencebetweenpoint1andpoint2.
Brg Azimuthbetweenpoint1andpoint2.