R6,Technical Data
104
14.4 DistanceMeasurementReflector(LongRange)
Range
Atmosphericconditions
Accuracy
Beaminterruptions,severeheatshimmerandmovingobjectswithinthebeampathcanresult
indeviationsofthespecifiedaccuracy.
Characteristics
14.5 ConformitytoNationalRegulations
14.5.1 Zoom20
Conformitytonationalregulations
A2,A4,A6,(withreflector) RangeA RangeB RangeC
[m] [ft] [m] [ft] [m] [ft]
Standardprism 2200 7300 7500 24600 >10000 >33000
Reflectorfoil
60 mmx60 mm
600 2000 1000 3300 1300 4200
Rangeofmeasurement: From1000 mupto12000 m
Displayunambiguous: Upto12 km
RangeA: Stronghaze,visibility5 km;orstrongsunlight,severeheatshimmer
RangeB: Lighthaze,visibilityabout20 km;ormoderatesunlight,slightheatshimmer
RangeC: Overcast,nohaze,visibilityabout40 km;noheatshimmer
Standard
measuring
ISO 171234 Measuretime,
typical[s]
Measuretime,
maximum[s]
Longrange 5 mm+2 ppm 2.5 12
Principle: Phasemeasurement
Type: Coaxial,visibleredlaser
Carrierwave: 658 nm
Measuringsystem: Systemanalyserbasis100 MHz‐150 MHz
Hereby,GeoMaxAG,declaresthattheinstrumentisincompliancewiththe
essentialrequirementsandotherrelevantprovisionsofapplicableEuropean
Directives.ThedeclarationofconformityisavailablefromGeoMaxAG.