EasyManua.ls Logo

STONEX R6 Series - As Built Check

STONEX R6 Series
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
R6,Applications
72
Nextstep
Either,pressAsBLT tocheckpointlocationsrelativetoacontructionline.
Or,press Shifttoenteroffsetvaluesforshiftingtheconstructionline.
9.11.3 AsBuiltCheck
Description
TheAsbuiltscreendisplaystheLine,Offsetandd.d.Zofameasuredpointinrelationtothe
constructionline.Theon‐screengraphicsshowthepositionofthemeasuredpointrelativeto
theconstructionline.
)
Theheightofthelinestartpointisalwaysusedasthereferenceheight!
Access
PressAsBLTfromthe LAY OUT screen.
ASBUILTCHECK
Thegraphicsarescaledtogiveabetteroverview.Thereforeitispossiblethatthestationpoint
movesinthegraphics.
AsBLT
ToswitchtoAsBuiltmodetocheckpointsrelativeto
theconstructionline.
Shift
Toentervaluesforshiftingtheline.
Field Description
dLi Longitudinaloffset:Positiveiftargetpointisfurtherawaythanthemeasured
point.
dOf Perpendicularoffset:Positiveiftargetpointistotherightofthemeasuredpoint.
d HG Heightoffset:Positiveiftargetpointishigherthanthemeasuredpoint.
LAYOUT
ToswitchtoLayoutmodetosetoutpoints.
Shift
Toentervaluesforshiftingtheline.
Field Description
dLi Longitudinaloffset:Positiveifmeasuredpointisfurtheralongtheconstruction
linefromthestartpoint.

Table of Contents