R6,Technical Data
102
Beaminterruptions,severeheatshimmerandmovingobjectswithinthebeampathcanresult
indeviationsofthespecifiedaccuracy.
Characteristics
14.3 Distancer,MeasurementswithoutReflectors(Reflectorlessmode)
Range
A2(withoutreflector)
A4(withoutreflector)
A6(withoutreflector)
EDMmeasuringmode StandarddeviationISO 171234 Measurementtime,typical[s]
IR‐Default 2 mm+2 ppm 2.4
IR‐Quick 5 mm+2 ppm 0.8
IR‐Continuous 5 mm+2 ppm <0.15
Foil 5 mm+2 ppm 2.4
Principle: Phasemeasurement
Type: Coaxial,visibleredlaser
Carrierwave: 658 nm
Measuringsystem: Systemanalyserbasis100 MHz‐150 MHz
KodakGrayCard RangeD RangeE RangeF
[m] [ft] [m] [ft] [m] [ft]
Whiteside,90 %reflective 150 490 180 590 ≤250 ≤820
Greyside,18 %reflective 80 260 100 330 ≤110 ≤360
KodakGrayCard RangeD RangeE RangeF
[m] [ft] [m] [ft] [m] [ft]
Whiteside,90 %reflective 200 660 300 990 >400 >1310
Greyside,18 %reflective 100 330 150 490 >200 >660
KodakGrayCard RangeD RangeE RangeF
[m] [ft] [m] [ft] [m] [ft]
Whiteside,90 %reflective 350 1150 450 1480 ≤600 ≤1970
Greyside,18 %reflective 200 660 250 820 ≤350 ≤1150
RangeofMeasurement: 1.5 mto1200 m