R6,Settings
21
4Settings
4.1 GeneralSettings
Access
1) SelectSettingsfromtheMAIN MENU.
2) SelectGeneralfromtheSETTINGS menu.
3) Press toscrollthroughthescreensofavailablesettings.
SETTINGS
DelLng
Todeleteaselectedlanguage.
Field Description
Contrast 0%to100% Setsthedisplaycontrastin10%steps.
Tilt Corr. Off Tiltingcompensationdeactivated.
Single Axis Verticalanglesrefertotheplummetline.
Dual Axis Verticalanglesrefertotheplummetlineandthehorizontal
directionsarecorrectedbythestandingaxistilt.
ForcorrectionsdependingontheHA Corr: setting,referto
thetable"Tiltandhorizontalcorrections".
)
Iftheinstrumentisusedonanunstablebase,forexampleashakingplatform
orship,thecompensatorshouldbedeactivated.Thisavoidsthecompensator
driftingoutofit'smeasuringrangeandinterruptingthemeasuringprocessby
indicatinganerror.
HA Corr. On Horizontalcorrectionsareactivated.Fornormaloperation
thehorizontalcorrectionshouldremainactive.Eachmeas‐
uredhorizontalanglewillbecorrected,dependingonthe
verticalangle.
ForcorrectionsdependingontheTilt Corr: setting,referto
thetable"Tiltandhorizontalcorrections".
Off Horizontalcorrectionsaredeactivated.
Face I Def. SetsthefaceIinrelationtothepositionoftheverticaldrive.
VA-Left SetsfaceItobewhentheverticaldriveisontheleftofthe
instrument.

Table of Contents