R6,Operation
20
Avoidinterruptingthemeasuringbeamwhiletakingreflectorlessmeasurementsor
measurementsusingreflectivefoils.
Donotmeasurewithtwoinstrumentstothesametargetsimultaneously.
IRmeasurements
AccuratemeasurementstoprismsshouldbemadeinIR‐Defaultmode.
MeasurementstostronglyreflectingtargetssuchastrafficlightsinPrismmodewithouta
prismshouldbeavoided.Themeasureddistancesmaybewrongorinaccurate.
Whenadistancemeasurementistriggered,theEDMmeasurestotheobjectwhichisinthe
beampathatthatmoment.Ifforexamplepeople,cars,animals,orswayingbranchescross
thelaserbeamwhileameasurementisbeingtaken,afractionofthelaserbeamis
reflectedfromtheseobjectsandmayleadtoincorrectdistancevalues.
Measurementstoprismsareonlycriticalifanobjectcrossesthemeasuringbeamata
distanceof0to30 mandthedistancetobemeasuredismorethan300 m.
Inpractice,becausethemeasuringtimeisveryshort,theusercanalwaysfindawayof
avoidingunwantedobjectsfrominterferringinthebeampath.
Redlasertoprism
RL‐LongRangemodeenablesdistancemeasurementsofover3.5 kmtostandardprisms
usingthevisibleredlaserbeam.
Redlasertoreflectorfoil
Thevisibleredlaserbeamcanalsobeusedtomeasuretoreflectivefoils.Toguaranteethe
accuracytheredlaserbeammustbeperpendiculartothereflectorfoilanditmustbewell
adjusted.
Makesuretheadditiveconstantbelongstotheselectedtarget(reflector).
Warning
Duetolasersafetyregulationsandmeasuringaccuracy,usingtheLongRangeReflectorless
EDMisonlyallowedtoprismsthataremorethan1000 m(3300 ft)away.