R6,Settings
25
Tiltandhorizontalcorrections
4.2 EDMSettings
Description
ThesettingsonthisscreendefinetheactiveEDM,ElectronicDistance Measurement.Different
settingsformeasurementsareavailablewithRecflectorless(RL)andPrism(IR)EDMmodes.
Access
1) SelectSettingsfromtheMAIN MENU.
2) SelectEDMfromtheSETTINGS menu.
EDMSETTINGS
Setting Correction
Tiltcorrec
tion
Horizontal
correction
Inclinelongi
tudinal
Inclinetrans
versal
Horizontal
collimation
Tiltingaxis
Off On No No Yes Yes
1-Axis On Yes No Yes Yes
2-Axis On Yes Yes Yes Yes
Off Off No No No No
1-Axis Off Yes No No No
2-Axis Off Yes No No No
ATMOS
Toenteratmosphericdatappm.
PPM
Toenteranindividualppmvalue.
SCALE
Toenterprojectionscaledetails.
SIGNAL
ToviewEDMSignalreflectionvalue.
FREQ.
ToviewtheEDMfrequency.
Field Description
Mode IR-Default Finemeasuringmodeforhighprecisionmeasurementswith
prisms.
IR-Quick Quickmeasuringmodewithprisms,withhighermeasuring
speedandreducedaccuracy.