11.4 CalibratingtheCircularLeveloftheInstrumentandTribrach
Calibratethecircularlevelstepbystep
1 Placeandsecurethetribrachontothetripod,andthensecuretheinstrumentontothe
tribrach.
2 Usingthetribrachfootscrews,leveltheinstrumentwiththeelectroniclevel.Toactivatethe
electroniclevel,turnontheinstrument,and,iftiltcorrectionissetto1‐or2‐axis,theLevel
& Plummetscreenappearsautomatically.Alternatively,pressFNCfromwithinanyappli‐
cationandselectLevel & Plummet.
3 Thebubblesoftheinstrumentandtribrachlevelsmustbecentered.Ifoneorbothcircular
levelsarenotcentered,adjustasfollows.
Instrument:Ifthebubbleextendsbeyondthecircle,usetheAllenkeysuppliedtocenterit
withtheadjustmentscrews.
Tribrach:Ifthebubbleextendsbeyondthecircle,adjustitusingtheadjustmentpinin
conjunctionwiththeadjustmentscrews.Turntheadjustmentscrews:
• Totheleft:andthebubbleapproachesthescrew.
• Totheright:andthebubblegoesawayfromthescrew.
Results out of toler-
ance. Previous values
retained !
Computedvaluesoutoftolerance.Thepreviousvaluesare
retainedandmeasurementsshouldberepeated.Confirmationof
themessagerequired.
HA-angle not suitable
for adjustment !
HorizontalangleinfaceIIdeviatesbymorethan5°fromthetarget
point.Aimonthetargetpointwithanaccuracyofmin.5°.Confir‐
mationofthemessagerequired.
Measurement Error.
Try again.
Measurementerrorappearswhen,forexample,thereisan
unstablesetup.Repeattheprocess.Confirmationofthemessage
required.
Time limit exceeded !
Please repeat adjust-
ment !
Timedifferencebetweenmeasurementsforresultsstorage
exceeds15minutes.Repeattheprocess.Confirmationofthe
messagerequired.