R6,Applications
63
• Status: Ontoactivateawarningmessageifthecalculatedstandarddeviation
exceedsthelimit.
• SettheaccuracylimitsfortheEasting,NorthingandHeightcoordinatesandthe
standarddeviationangle.
• PressOKtosavethelimitsandreturntothePre-settingsscreen.
5) SelectGO!tobegintheapplication.
Entertargetdata
EnterthenameofthestationandtheheightoftheinstrumentintheStation data screenand
pressOK.
Nextstep
ToaccesstheSight target point screen:
• Either,pressOKafterenteringthetargetdatafieldsintheTarget datascreen.
• Or,press SKIPtoskipenteringthetargetdatafieldsagainwhenmeasuringthe
samepointinanotherface.
Sighttargetpoint
IntheSight target pointscreen:
2 / I: IndicatesthatthesecondpointwasmeasuredinfaceI.
2 / I II: IndicatesthatthesecondpointwasmeasuredinfacesIandII.
Nextstep
• Either,pressNextPttomeasurethenextknownpoint.
• Or,pressCALC.tocalculatethestationposition.
9.7.2 MeasuringInformation
Measurementsequences
Thefollowingmeasurementsequencesarepossible:
• Horizontaldirectionandvertical‐anglesonly(resection)
• Distanceandhorizontaldirectionandvertical‐angle
• Horizontaldirectionandvertical‐anglestosomepoint(s)andhorizontaldirectionand
verticalanglesplusdistancetootherpoint(s).
SinglefaceI,singlefaceII,ordualfaceIandIImeasurementsarealwayspossible.Nospecific
pointsequenceorspecificfacesequencesarerequired.
CALC.
Tocalculateanddisplaythestationcoordinates,ifat
leasttwopointsandadistanceweremeasured.
NextPt
ToreturntotheEnter target datascreentoselect
thenextknownpoint.