R6,Calibration
82
Access
1) SelectToolsfromtheMAIN MENU.
2) SelectCalibr.fromtheTOOLS MENU.
• Select:
• HA-collimation,or
• Vertical Index.
)
Theproceduresandconditionsrequiredtocorrectline‐of‐sightandverticalindexerrorsare
thesame,thereforetheprocedurewillonlybedescribedonce.
Calibrationstepbystep
1) Leveltheinstrumentwiththeelectroniclevel.Referto"3Operation"‐"Levelupwiththe
electroniclevelstep‐by‐step".
3 PressRECtomeasuretothetargetpoint.
5 PressRECtomeasuretothetargetpoint.
6Either:
• PressOKtosavethenewcalibrationdata,or
• PressESCtoexitwithoutsavingthenewcalibrationdata.
Messages
Thefollowingareimportantmessagesorwarningsthatmayappear.
2 Aimatapointapproximately100 mfromtheinstru‐
mentwhichiswithin5°ofthehorizontal.
4 Changefaceandaimatthetargetpointagain
)
Forcheckingthehorizontalaim,thedifferenceinHAandVAaredisplayed.
)
Theoldandnewcalculatedvaluesaredisplayed.
Messages Description
VA-angle not suitable
for adjustment !
Theverticalangledeviatesfromtherequiredhorizontal/line‐of‐
sight,orinfaceIItheverticalangledeviatesbymorethan5°from
thetargetpoint.Aimatthetargetpointwithanaccuracyofmin.5°.
Confirmationofthemessagerequired.