R6,Technical Data
103
Atmosphericconditions
Accuracy
Beaminterruptions,severeheatshimmerandmovingobjectswithinthebeampathcanresult
indeviationsofthespecifiedaccuracy.
* Accuracyandmeasuretimedependonatmosphericconditions,targetobjectandobserva‐
tionsituation.
Characteristics
Laserdotsize
Displayunambiguous: upto1200 m
RangeD: Objectinstrongsunlight,severeheatshimmer
RangeE: Objectinshare,orovercast
RangeF: Day,nightandtwilight
Standard
measuring
ISO 171234 Measuretime,
typical[s]
Measuretime,
maximum[s]
0 m‐500 m 3 mm+2 ppm 3‐6 12
>500 m 4 mm+2 ppm 3‐6 12
Continuousmeasuring* Standarddeviation Measuretime,typical[s]
Continuous 5 mm+3 ppm 0.25
Type: Coaxial,visibleredlaser
Carrierwave: 658 nm
Measuringsystem: Systemanalyserbasis100 MHz‐150 MHz
Distance[m] Laserdotsize,approximately[mm]
at30 7x10
at50 8x20