R6,Applications - Getting Started
44
Access
SelectCoordinatesintheSTN-ORIENTATIONscreen.
Orientationwithcoordinates
Nextstep
FindanexistingbacksightpointinthepointsearchorenterENZcoordinatesforanewpoint.
PressOKtocontinuetoSight target point.
Sighttargetpoint
Nextstep
Aftereachmeasurementthemessage,Do you want to take additional measurements
appears.Selecting:
YesreturnstotheSight target pointscreentotakeanadditionalmeasurement.A
maximumoffivetargetpointscanbeused.
NoproceedstotheSTN. ORIENTATION RESULTscreen.
Resultcalculation
Ifmorethanonetargetpointismeasuredthentheorientationiscomputedusingthe"least
squaresmethod".
Stn.Orientationresult
Field Description
Pt. PointIDofthebacksightpoint.
Field Description
BS ID PointIDoftheselected,orenteredbacksightpoint.
IF THEN
theorientationisonlymeasuredinfaceII thehorizontaldirectionisbasedonfaceII.
theorientationismeasuredonlyinfaceIor
amixtureofIandII
thehorizontaldirectionisbasedonfaceI.
atargetpointismeasuredseveraltimesin
thesameface
thelastvalidmeasurementisusedforthe
computation.
Field Description
Pts Numberofpointsusedinthecalculation.
Stn Stationnameforwhichtheorientationhasbeenset.
HA Corr Horizontalcorrection