Battery Setup Page
Tocongurebatterysettings,clickontheBATTERYiconandthenon‘Batttype’.
What this page displays:
Battery capacity in (Ah): For non-BMS-batteries the range allowed is 0-2000Ah, while for lithium-ion,
the inverter will use the capacity value of the BMS.
Charge/Discharge Amps: The Max battery charge/discharge current (0-50A for 50kW model).
AGM V: Use battery voltage for all settings (V).
AGM %: Use battery SOC for all settings (%).
No batt: Tick this box if no battery is connected to the system.
BMS_Err_Stop: When it is active, if the battery BMS fails to communicate with inverter, the inverter will
stop working and report fault.
Active battery: This feature will help recover a battery that is 100% discharged by slowly changing from
the solar array. Until the battery reaches a point where it can change normally.
TEMPCO settings: Thetemperaturecoecientistheerrorintroducedbyachangeintemperature.
NOTE:
Recommended:
AGM and Flooded: Ah battery size x 20% = Charge/Discharge amps.
Lithium: Ah battery size x 50% = Charge/Discharge amps.
Gel: follow manufacturer's instructions.